The numbers below refer to the step numbers on the diagnostic table.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics Connector End View Reference: Master Electrical Component List | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Important:: The sun load sensor assembly must indicate low light conditions for the courtesy lamps to operate.
Does the ignition key cylinder lamp operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Do the courtesy lamps operate properly? | Go to Step 4 | Go to Courtesy Lamps Always On and Courtesy Lamps Inoperative |
Does the ignition key cylinder lamp turn ON and OFF with each command? | Go to Step 9 | Go to Step 5 | |
5 |
Does the test lamp turn ON and OFF with each command? | Go to Step 8 | Go to Step 6 |
6 | Test the battery positive voltage circuit of the ignition key cylinder lamp for high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 7 |
7 | Test the key cylinder lamp control circuit of the ignition key cylinder lamp for a high resistance or open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 9 |
8 | Inspect for poor connections at the ignition key cylinder lamp bulb. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 10 |
9 | Inspect for poor connections at the harness connector of the IPM with CJ2 or the HVAC control module (CCP) with C67. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 11 |
10 | Replace the ignition key cylinder lamp bulb. Refer to Ignition Lock Cylinder Bulb Replacement . Did you complete the replacement? | Go to Step 12 | -- |
11 |
Important: After replacement, perform the setup procedure for the IPM. Refer to Body Control Module (BCM) Programming/RPO Configuration in Body Control System. Replace the IPM with CJ2 or HVAC control module (CCP) with C67. Refer to Instrument Panel Module Replacement in Body Control System or HVAC Control Module Replacement in HVAC Systems - Manual. Did you complete the replacement? | Go to Step 12 | -- |
12 | Operate the system in order to verify the repair. Did you find and correct the condition? | System OK | Go to Step 2 |