Heated oxygen sensors (HO2S) are used in order to minimize the amount of time required for closed loop fuel control operation, and to allow accurate catalyst monitoring. The oxygen sensor heater greatly decreases the amount of time required for the fuel control sensor HO2S 1 to become active. The oxygen sensor heater is required by the catalyst monitor sensor HO2S 2 in order to maintain a sufficiently high temperature. This allows accurate exhaust oxygen content readings further from the engine.
The poertrain control module (PCM) will run the heater test only after a cold start, determined by the engine coolant and the intake air temperature at the time of startup, and will run the test only once during an ignition cycle. When the engine is started, the PCM will monitor the HO2S voltage. When the Bank HO2S voltage indicates a sufficiently active sensor, the PCM looks at how much time has elapsed since start-up. If the PCM determines that too much time was required for the HO2S 2 to become active, the DTC will set. The time the HO2S should take to reach operating temperature is based on the engine coolant temperature at start-up and the average mass air flow (MAF) since startup. More total airflow or a higher start-up engine coolant temperature equals a shorter time to HO2S activity.
• | DTCs P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0117, P0118, P0121, P0122, P0123, P0125, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0410, P0440, P0442, P0443, P0446, P0449, or P1441are not set. |
• | The system voltage is between 9-16 volts. |
• | The intake air temperature (IAT) is less than 35°C (95°F) at start-up. |
• | The engine coolant temperature (ECT) is less than 35°C (95°F) at start-up. |
• | The IAT and ECT are within 6°C (11°F) of each other at start-up. |
• | The average mass air flow (MAF) for the sample period is less than 24 g/s for VIN K. |
• | The average mass airflow for the sample period is less than 27 g/s for VIN 1. |
VIN K--The HO2S 2 voltage remains within 150 mV of the bias voltage, or approximately 450 mV, for more time than necessary. The time ranges between 2-3 minutes, depending upon the engine coolant temperature at start-up and on the average air flow since start-up.
VIN 1--The HO2S 2 voltage remains within 150 mV of the bias voltage, or approximately 450 mV, for more time than necessary. The time ranges between 1.5-2 minutes, depending upon the engine coolant temperature at star-tup and on the average air flow since start-up.
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
The numbers below refer to the step numbers on the diagnostic table:
The HO2S should be allowed to cool before performing this test. If the HO2S heater is functioning, the signal voltage will gradually increase or decrease as the sensor element warms. If the heater is not functioning, the HO2S signal will remain near the 450 mV bias voltage.
This step ensures that the ignition 1 voltage circuit to the HO2S is not open or shorted. The test lamp should be connected to a good chassis ground, in case the HO2S low signal or HO2S heater ground circuit is malfunctioning.
This step checks the HO2S heater ground circuit.
This step checks for an open or shorted HO2S heater element.
An open HO2S high signal or HO2S low signal circuit can cause the DTC to set with a good HO2S. Check the HO2S high signal and the HO2S low signal circuits before replacing the sensor.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: Engine Controls Schematics | ||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |
Important: If the engine has been operating, allow the engine to cool for about one-half hour before proceeding.
Does the HO2S voltage change from bias voltage to more than the first specified value, or to less than the second specified value within 2 minutes? | 600 mV 300 mV | Go to Intermittent Conditions | Go to Step 3 | |
3 | Inspect the fuse for the HO2S 2 ignition 1 voltage circuit. Is the fuse open? | -- | Go to Step 15 | Go to Step 4 |
Important: Use a known good ground. Do not use the HO2S 2 heater ground or the HO2S 2 low signal circuit. Does the test lamp illuminate? | -- | Go to Step 5 | Go to Step 7 | |
Connect the test lamp between the HO2S ignition 1 voltage and the HO2S 2 heater ground. Does the test lamp illuminate? | -- | Go to Step 6 | Go to Step 8 | |
Does the resistance measure within the specified range? | 5-6 ohms | Go to Step 9 | Go to Step 14 | |
7 | Repair open HO2S ignition 1 voltage circuit to the HO2S 2. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- |
8 | Repair an open HO2S heater ground circuit. Refer to Heated Oxygen Sensor Wiring Repairs in Wiring Systems . Did you complete the repair? | -- | Go to Step 16 | -- |
9 |
Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 10 |
10 |
Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 11 |
Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 12 | |
12 |
Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 13 |
13 |
Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 14 |
14 | Replace the HO2S 2. Refer to Heated Oxygen Sensor 2 Replacement . Did you complete the replacement? | -- | Go to Step 16 | -- |
15 | Repair any short to ground in the HO2S ignition 1 voltage circuit, and replace the fuse. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- |
16 |
Does the DTC run and pass? | -- | Go to Step 17 | Go to Step 2 |
17 | With a scan tool observe the stored information in Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | -- | System OK |