Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Disconnect the IP compartment lamp.
- Connect a fused jumper from the IP compartment lamp switch terminal
A to terminal B.
Does the test lamp light?
| --
|
Go to Step 2
|
Go to Step 3
|
2
|
- Test for a poor connection at the IP compartment lamp.
- If the connections are OK, replace the IP compartment lamp. Refer
to
Instrument Panel Compartment Lamp Replacement
.
Is the repair complete?
| --
| System
OK
| --
|
3
| Connect a test lamp
from IP compartment lamp switch connector terminal A to ground.
Does the test lamp light?
| --
|
Go to Step 5
|
Go to Step 4
|
4
|
- Test for a poor connection at the IP compartment lamp connector
terminal A.
- If the connection is OK, repair the open in circuit 149 from the
IP compartment lamp connector to S149.
Is the repair complete?
| --
| System
OK
| --
|
5
|
- Test for a poor connection at the IP compartment lamp connector
terminal B.
- If the connection is OK, reoair the open in circuit 650 between
the IP compartment lamp and S217.
Is the repair complete?
| --
| System
OK
| --
|