This operational test sequence aids in determining whether
the following systems are working properly:
Functional Check
Step
| Action
| Normal Result(s)
| Abnormal Result(s)*
|
1
|
- Place the mode control knob in the OFF position.
- Place the temperature control knob in the COLD (blue) position.
- Place the blower motor knob in the LOW fan position.
|
• | The blower motor speed is OFF. |
• | There is no airflow from the heater outlets. |
• | There is no airflow from the A/C outlets. |
• | There is no air flow from the defroster outlets. |
|
• | Airflow from the heater, A/C, or defroster outlets. |
• | Apply vacuum to each vacuum line individually (except black and
orange) |
• | If air flows out the outlets repair or replace the actuator linkage
and/or air valve (door). |
|
2
|
- Place the mode control knob in the MAX A/C setting.
- Place the temperature control knob in the COLD setting.
- Place the blower motor knob in the LOW setting.
|
• | The blower motor speed is LOW. |
• | There is no airflow from the heater outlets. |
• | There is airflow from the A/C outlets. |
• | There is no air flow from the defroster outlets. |
• | Temperature from the center A/C outlet should drop 11°C (20°F)
from the temperature outside the vehicle. |
• | Engagement of the detent is felt in each mode. |
|
• | Airflow from the heater or defroster outlets. No airflow from
the A/C outlets. |
• | Temperature does not change. |
• | No blower motor speed change. |
• | Blower motor speed inop. |
|
3
|
- Place the mode control knob in the MAX A/C setting.
- Place the temperature control knob in the COLD setting.
- Place the blower motor knob in the LOW to HIGH setting.
|
• | The blower motor speed is LOW to HIGH. |
• | There is no airflow from the heater outlets. |
• | There is airflow from the A/C outlets. |
• | There is no air flow from the defroster outlets. |
• | Temperature from the center A/C outlet should drop 11°C (20°F)
from the temperature outside the vehicle. |
• | A noticeable blower speed increase occurs from the following settings: |
• | The outlets hold their position during high blower motor speed
and are moveable by hand. |
|
• | There is airflow from the heater and/or defroster outlets. |
• | There is no airflow from the A/C outlets. |
• | Temperature does not change. |
• | No blower motor speed change. |
• | Blower motor speed inop. |
|
4
|
- Place the mode control knob in the NORMAL A/C setting.
- Place the temperature control knob in the COLD setting.
- Place the blower motor knob in the HIGH setting.
|
• | The blower motor speed is HIGH. |
• | There is no airflow from the heater outlets. |
• | There is airflow from the A/C outlets. |
• | There is no air flow from the defroster outlets. |
• | Listen for a reduction of air noise due to the recirculation door
closing. |
• | Engagement of the detent is felt in each mode control setting. |
|
• | There is airflow from the heater and/or defroster outlets. |
• | There is no airflow from the A/C outlets. |
• | Temperature does not change. |
• | No blower motor speed change. |
|
5
|
- Place the mode control knob in the BI-LEVEL A/C setting.
- Place the temperature control knob in the COLD setting.
- Place the blower motor knob in the HIGH setting.
|
• | The blower motor speed is HIGH. |
• | There is airflow from the heater outlets. |
• | There is airflow from the A/C outlets. |
• | There is minimum air flow from the defroster outlets. |
• | Engagement of the detent is felt in each mode control setting. |
|
• | Blower motor speed inop. |
• | Airflow from the heater outlets. |
• | No airflow from the A/C outlets. |
• | No engagement of the detent is felt. |
|
6
|
- Place the mode control knob in the VENT setting.
- Place the temperature control knob in the COLD setting.
- Place the blower motor knob in the HIGH setting.
|
• | The blower motor speed is HIGH. |
• | There is no airflow from the heater outlets. |
• | There is airflow from the A/C outlets. |
• | There is no air flow from the defroster outlets. |
• | Engagement of the detent is felt in each mode control lever setting. |
|
• | Blower motor speed inop. |
• | Airflow from the heater and/or defroster outlets. |
• | No airflow from the A/C outlets. |
• | No engagement of the detent is felt. |
|
7
|
- Place the mode control knob in the HEATER setting.
- Place the temperature control knob in the HOT setting.
- Place the blower motor knob in the HIGH setting.
|
• | The blower motor speed is HIGH. |
• | There is airflow from the heater outlets. |
• | There is no airflow from the A/C outlets. |
• | There is minimum air flow from the defroster outlets. |
• | Engagement of the detent is felt in each mode control lever setting. |
• | The temperature lever travels from full COLD to full HOT. |
• | Air flow is present at the side window defogger outlets. |
|
• | Blower motor speed inop. |
• | Airflow from the heater, defroster and A/C outlets. |
• | No engagement of the detent is felt. |
|
8
|
- Place the mode control knob in the DEFROSTER BLEND setting.
- Place the temperature control knob in the HOT setting.
- Place the blower motor knob in the HIGH setting.
|
• | The blower motor speed is HIGH. |
• | There is airflow from the heater outlets. |
• | There is no airflow from the A/C outlets. |
• | There is air flow from the defroster outlets. |
• | Engagement of the detent is felt in each mode control lever setting. |
• | Air flow is present at the side window defogger outlets. |
|
• | Blower motor speed inop. |
• | No airflow from the heater and/or defroster outlets. |
• | Airflow from the A/C outlets. |
• | No engagement of the detent is felt. |
• | No airflow at the side window defogger outlets. |
|
9
|
- Place the mode control knob in the DEFROST setting.
- Place the temperature control knob in the HOT setting.
- Place the blower motor knob in the HIGH setting.
|
• | The blower motor speed is HIGH. |
• | There is minimum airflow from the heater outlets. |
• | There is no airflow from the A/C outlets. |
• | There is air flow from the defroster outlets. |
• | Engagement of the detent is felt in each mode control lever setting. |
• | Air flow is present at the side window defogger outlets. |
|
• | Blower motor speed inop. |
• | Airflow from the A/C outlets. |
• | No airflow from the defroster outlets. |
• | No engagement of the detent is felt. |
• | No airflow at the side window defogger outlets. |
|
* Refer to the appropriate symptom diagnostic table for
the applicable abnormal result.
|