Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Was the Backup Light System Check performed? | -- | Go to Step 2 | Go to Backup Lamp System Check |
2 |
Does the switch test OK? | -- | Go to Step 3 | Go to Step 4 |
3 | Repair the short to voltage in the RED wire between the switch and S401. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Backup Lamp System Check | |
4 | Replace the switch. Refer to Backup Lamp Switch Replacement in Manual Transmission or Transaxle Range Switch in Automatic Transmission. Is the repair complete? | Go to Backup Lamp System Check |