Step | Action | Value | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||
2 |
Does the ECT gauge indicate H? | -- | Go to Step 3 | Go to Step 5 | ||||
3 | Inspect for a poor connection at the ECT sensor. Is the connection OK? | -- | Go to Step 4 | Go to Step 9 | ||||
4 | Replace the ECT sending unit. Is the repair complete? | -- | -- | |||||
5 |
Is the resistance greater than the specified value? | 2.0 ohms | Go to Step 6 | Go to Step 7 | ||||
6 | Repair the YEL/WHT wire between the instrument panel cluster assembly and the ECT sensor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||
7 | Inspect the instrument cluster printed circuit for the following conditions:
Do the above conditions exist? | -- | Go to Step 10 | Go to Step 8 | ||||
8 | Replace the ECT gauge. Is the repair complete? | -- | -- | |||||
9 | Repair the faulty connection. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||
10 | Replace the instrument cluster assembly. Refer to Printed Instrument Cluster Circuit Replacement in Instrument Panel Gauges, and Console. Is the repair complete? | -- | -- |