S13 is the Folding Top Front Location Pin Position switch. The Folding Top Control (FTC) Module uses S13 to determine if the folding top is stored in the rear compartment. S13 closes and pulls the signal circuit low when the folding top is not stored in the rear compartment.
The Folding Top Control (FTC) module is being commanded.
An open or short to ground is detected on the signal circuit of S13.
The top is disabled.
The fault is no longer present and the top completes one cycle.
• | DTC B1010 08 will set in conjunction with DTC B367F. |
• | A weak battery may cause DTC B367F 59 to set. |
• | A short to B+ may damage S13. |
Power Roof Systems Connector End Views
Power Folding Top Description and Operation
⇒ | If scan tool does not indicate In Position, test the signal circuit of S11 for a short to ground. |
⇒ | If circuit OK, replace FTC Module. |
⇒ | If scan tool does not indicate Not In Position, test the signal circuit of S13 for an open or high resistance. |
⇒ | If circuit OK, replace FTC Module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.