GM Service Manual Online
For 1990-2009 cars only

Interior Noise from HVAC Blower Fan (Remove All Remaining Foam Rubber Seal from Leaf Screen)

Subject:Interior Noise From HVAC Blower Fan (Remove Remaining Foam Rubber Seal from Leaf Screen)

Models:2004-2005 Pontiac GTO



Condition

Some customers may comment on interior noise from the HVAC blower fan.

Cause


Object Number: 1673517  Size: SH

This noise may be caused by loose foam rubber particles that come in contact with the blower fan. The foam rubber may have come from the seal which is attached to the leaf screen, located at the A/C evaporator air intake (item 3 shown in the illustration).

Correction

If investigation of blower fan noise indicates the cause to be particles of loose foam rubber in the blower fan, remove all remaining foam rubber seal from the leaf screen and refit the screen without the seal.

Warranty Information

For vehicles repaired under warranty, use:

Labor Operation

Description

Labor Time

D2000*

Air Inlet Screen, Engine Compartment (Heater Module) - R&R or Replace

0.3 hr

*This labor operation can be claimed in addition to D1322 (Blower Motor R&R).