Step
| Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | ||||
1 | Was the door locks system check performed? | -- | Go to Step 2 | |
2 | Perform the body control module (BCM) diagnostic system check. Are any door lock DTCs present? | -- | Go to Step 3 | |
3 |
Does the output change from OFF to ON? | -- | Go to Step 4 | Go to Step 10 |
4 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 5 |
5 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 |
6 | Replace the door lock relay. Is the repair complete? | -- | -- | |
7 | Replace the left IP junction block. Is the repair complete? | -- | -- | |
8 |
Does the test lamp light? | -- | Go to Step 9 | Go to Step 11 |
9 | Repair open or short to ground in CKT 195 between the BCM and left IP junction block connector C1. Is the repair complete? | -- | -- | |
10 |
Is the voltage as specified? | 12-14V | Go to Step 12 | Go to Step 11 |
11 | Inspect for a poor connection at the BCM connectors. If OK, replace the BCM. Is the repair complete? | -- | -- | |
12 |
Is the reading less than the specified value? | 1V | Go to Step 13 | |
13 | Replace the lock switch(es) that pulled less than the specified value when activated to the LOCK position. Is the repair complete? | 1V | -- |