Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | ||||
1 | Was the power door locks system check performed? | -- | Go to Step 2 | |
2 | Perform the body control module (BCM) diagnostic system check. Are any door lock DTCs present? | -- | Go to Step 3 | |
3 |
Is the voltage as specified? | B+ | Go to Step 4 | Go to Step 5 |
4 | Replace the door lock switch. Is the repair complete? | -- | -- | |
5 |
Is the voltage as specified? | B+ | Go to Step 6 | Go to Step 7 |
6 | Repair the open in CKT 650 between the door lock switch and ground splice pack G302. Is the repair complete? | -- | -- | |
7 | Repair the open in CKT 682 between the right IP junction block connector C3 terminal B4 and the door lock switch. Is the repair complete? | -- | -- |