When the BCM receives a class 2 signal from the power control module (PCM) indicating the gear selector is in the REVERSE position, the BCM applies battery positive voltage to the backup lamps voltage supply circuit. The backup lamps are grounded at G302.
The battery voltage must be between 9.0-16.0 volts.
DTC B2545 is set when the backup lamps supply voltage circuit is shorted to ground or opened.
The backup lamps will not operate.
• | This DTC will clear on current status after the condition for setting the fault is corrected. |
• | A history DTC will clear after 100 consecutive ignition cycles without a fault present. |
• | History DTC(s) can be cleared using a scan tool. |
Perform a visual inspection for loose or poor connections at all related components. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Master Electrical Component List in Wiring Systems | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Do the backup lamps turn ON and OFF with each command? | Go to Diagnostic Aids | Go to Step 3 |
3 | Test the backup lamps voltage supply circuit for a short to ground or an open. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 5 | Go to Step 4 |
4 |
Important: Always perform the setup procedure for the BCM.
Did you complete the replacement? | Go to Step 5 | -- |
5 |
Does the DTC reset? | Go to Step 2 | System OK |