• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Backup Lamp Voltage Supply | 2 | 2 | 1 | |
Backup Lamp Switch Voltage Supply | 2 | 2 | -- | -- |
Backup Lamp - Left Ground | -- | 2 | 2 | -- |
Backup Lamp - Right Ground | -- | 2 | 2 | -- |
1. Backup Lamps Always On 2. Backup Lamps Inoperative |
Battery voltage is applied to the backup lamp switch when the ignition switch is in the RUN or CRANK positions. When the transmission is placed in the REVERSE position, the backup lamp switch provides battery voltage to the backup lamps. The backup lamps are permanently grounded at G402. With both power and ground the backup lamps illuminate. Once the driver moves the gear selector out of the REVERSE position, the backup lamp switch contacts open and the backup lamps turn OFF.
Lighting Systems Connector End Views
⇒ | If the backup lamps remain illuminated, repair the backup lamp voltage supply circuit for a short to voltage. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Backup Lamp Switch Replacement
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Backup Lamp Relay Control | 1 | 2 | 2 | -- |
Backup Lamp Voltage Supply | 2 | 2 | 1 | |
Backup Lamp - Left Ground | -- | 2 | 2 | -- |
Backup Lamp - Right Ground | -- | 2 | 2 | -- |
1. Backup Lamps Always On 2. Backup Lamps Inoperative |
The underhood fuse block supplies battery positive voltage to the coil and switch terminals of the backup lamps relay. When the transmission is placed in the REVERSE position, the transmission control module (TCM) sends a message via GMLAN to the body control module (BCM). The message indicates that the gear selector is in the REVERSE position. The BCM grounds the backup lamp relay control circuit which energizes the backup lamps relay. With the relay energized, the switch side contacts close and provide battery voltage to the backup lamps fuse through to the backup lamps. The backup lamps are permanently grounded at G402. With both power and ground the backup lamps illuminate. Once the driver moves the gear selector out of the REVERSE position, a message is sent by the TCM via GMLAN serial data requesting the BCM to remove ground from the backup lamp relay control circuit. This opens the backup lamps relay switch contacts turning OFF the backup lamps.
Lighting Systems Connector End Views
⇒ | If the scan tool displays ON, replace the BCM. |
⇒ | If the backup lamps remain illuminated, repair the backup lamp voltage supply circuit for a short to battery voltage. |
⇒ | If the test lamp illuminates, repair the reverse lamp relay control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |