Important: Load testing requires the use of battery side terminal adapters (AC
Delco part number ST-1201, GM P/N 12303040 or equivalent) to ensure good
connections. Do not load test a frozen battery. Replace it instead.
- Use a voltmeter to check the voltage across the terminals. With all
loads off, and the green dot showing in the hydrometer, the voltage should
be 12 volts or higher. If not, Refer to
Battery Replacement
.
- With voltmeter still attached, connect a battery load tester across
the battery terminals.
- If the battery has been on charge, apply a 300 ampere load
test for 15 seconds to remove surface charge from the battery. Remove the
load. (Do not complete this step if the battery has not been recently charged).
- Wait 15 seconds to let the battery recover. Apply the specified
load located on the battery label or Refer to
Battery Usage
.
Read the voltage after 15 seconds, them remove the load.
- If the voltage does not drop below the minimum, the battery is
good and should be returned to service. (The battery temperature must be estimated
by feel and by the temperature the battery has been exposed to for the proceeding
few hours). Refer to
Battery Temperature Versus Voltage Drop
.
- If the voltage drops below the minimum listed, Refer to
Battery Replacement
.