Removal Procedure
- Remove the nut from the accessory wiring junction block.
- Remove the accessory wiring junction block from the diagonal cross
brace.
- Remove the diagonal cross brace. Refer to Section 10-5.
- Disconnect the battery ground (negative) cable. Refer to Battery
Disconnect Caution in General Information.
- Disconnect the battery (positive) cable.
- Remove the battery hold down retainer.
Important: Do not tip the battery more than 40 degrees during removal.
- Remove the battery.
- Remove the battery insulator from the battery.
Installation Procedure
- Install the battery insulator to the battery.
Important: Do not tip the battery more than 40 degrees during installation.
- Install the battery.
- Install the battery hold down retainer.
- Install the battery (positive) cable to the battery.
Tighten
Tighten the battery (positive) cable to 15 N·m (11 lb
ft).
- Install the battery ground (negative) cable to the battery. Refer
to Battery Disconnect Caution in General Information.
- Install the diagonal cross brace. Refer to Section 10-5.
- Install the accessory wiring junction block form the diagonal
cross brace.
- Install the nut from the accessory wiring junction block.