• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Signal | B0980 | 1 | -- | -- |
Ground | -- | 1 | -- | -- |
Transmission Hold Mode Inoperative |
The transmission hold switch is an input to the instrument panel cluster (IPC). The switch signal circuit is supplied a reference voltage from the IPC. When the hold switch is pressed the reference voltage is closed to ground. When the reference voltage is low the switch is determined to be active.
Ignition voltage is greater than 9.5 V.
The hold switch signal circuit is low for greater than 60 seconds.
The transmission hold mode will be disabled.
The current DTC clears when the fault is no longer present.
Control Module References for scan tool information
Ignition ON, observe the scan tool Hold Switch parameter while pressing and releasing the hold switch. The reading should change between Active and Inactive.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the IPC. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the IPC. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for IPC replacement, programming, and setup.