GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Remove the right instrument panel (I/P) insulator. Refer to Instrument Panel Insulator Panel Replacement - Right Side in Instrument Panel, Gages, and Console.
  2. Remove the I/P compartment. Refer to Instrument Panel Compartment Replacement in Instrument Panel, Gages, and Console.

  3. Object Number: 1194925  Size: SH
  4. Remove the screws that secure the mode actuator (1) to the HVAC module assembly.
  5. Remove the mode actuator from the HVAC module assembly.
  6. Disconnect the electrical connector from the mode actuator.

Installation Procedure

  1. Position the mode actuator, aligning the slots in the electric actuator drive to the flats on the shaft.
  2. Align the locating hole to the alignment pin on the HVAC module assembly.
  3. Slide the actuator drive completely onto the shaft, with the mounting holes flush with the mounting screw holes on the HVAC module assembly.
  4. Notice: Refer to Fastener Notice in the Preface section.


    Object Number: 1194925  Size: SH
  5. Install the screws to the mode actuator (1).
  6. Tighten
    Tighten the screws to 1.5 N·m (13 lb in).

  7. Connect the electrical connector to the mode actuator.
  8. Install the I/P compartment. Refer to Instrument Panel Compartment Replacement in Instrument Panel, Gages, and Console.
  9. Install the right I/P insulator. Refer to Instrument Panel Insulator Panel Replacement - Right Side in Instrument Panel, Gages, and Console.
  10. Calibrate the actuator. Refer to Actuator Recalibration .