Removal Procedure
- Remove the right side instrument panel (I/P) insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument
Panel, Gages and Console.
- Remove the I/P compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages and Console.
- Remove
the screws retaining the air temperature actuator (2).
- Disconnect the electrical connector from the air temperature actuator.
- Remove the air temperature actuator from the HVAC Module Assembly.
Installation Procedure
- Position
the air temperature actuator (2). Align the slots in the electric actuator driver
to the flats on the shaft.
- Align the locating hole to the alignment pin on the HVAC module case.
- Slide the actuator driver on the shaft. The actuator driver should sit
completely on the shaft and the mounting holes should be flush with the HVAC module
case.
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws to the air temperature actuator.
Tighten
Tighten the screw to 1.5 N·m (13 lb in).
- Connect the electrical connector to the air temperature actuator.
- Install the I/P compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Install the right side I/P insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages,
and Console.
- Calibrate the actuator. Refer to
Actuator Recalibration
.