Table 1: | HO2S Voltages |
The wide band heated oxygen sensor (HO2S) measures the amount of oxygen in the exhaust system and provides more information than the switching style HO2S. The wide band sensor consists of an oxygen sensing cell, an oxygen pumping cell, and a heater. The exhaust gas sample passes through a diffusion gap between the sensing cell and the pumping cell. The engine control module (ECM) supplies a voltage to the HO2S and uses this voltage as a reference to the amount of oxygen in the exhaust system. An electronic circuit within the ECM controls the pump current through the oxygen pumping cell in order to maintain a constant voltage in the oxygen sensing cell. The ECM monitors the voltage variation in the sensing cell and attempts to keep the voltage constant by increasing or decreasing the amount of current flow, or oxygen ion flow, to the pumping cell. By measuring the amount of current required to maintain the voltage in the sensing cell, the ECM can determine the concentration of oxygen in the exhaust. The HO2S voltage is displayed as a lambda value. A lambda value of 1 is equal to a stoichiometric air fuel ratio of 14.7:1. Under normal operating conditions, the lambda value will remain around 1. When the fuel system is lean, the oxygen level will be high and the lambda signal will be high or more than 1. When the fuel system is rich, the oxygen level will be low, and the lambda signal will be low or less than 1. The ECM uses this information to maintain the correct air/fuel ratio.
This diagnostic procedure supports the following DTC:
DTC P0132 HO2S Circuit High Voltage Sensor 1
• | The engine is operating. |
• | The ignition 1 voltage is between 10.7-18 volts. |
• | DTC P0132 runs continuously once the above conditions are met for more than 2 seconds. |
• | The internal ECM HO2S voltage is more than a threshold. |
• | The above condition exists for more than 4 seconds. |
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 4 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
The following table illustrates the ECM connector locations:
ECM Connector Location | |
---|---|
C2 | C1 |
Front of Vehicle |
• | Use the J 35616-A/BT-8637 Connector Test Adapter Kit for any test that requires probing the ECM harness connector or a component harness connector. |
• | The front wide band sensors do not toggle or switch like a switching HO2S. The front HO2S signals will be relatively stable for an idling engine. |
• | High resistance in any of the HO2S circuits could cause this DTC to set. |
• | For an intermittent condition, refer to Intermittent Conditions . |
• | This DTC sets if the heater control circuit is shorted to any other HO2S circuit. The following table illustrates the typical voltages for the HO2S circuits. |
HO2S Circuit | Voltage | ||||
---|---|---|---|---|---|
| |||||
Heater Control | 4.6-5.0 V | ||||
Heater Supply Voltage | B+ | ||||
Reference Voltage | 2.6-3.1 V | ||||
Low Reference | 2.2-2.7 V | ||||
Pump Current | Less than 0.5 V | ||||
Input Pump Current | Less than 0.5 V |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the condition exists. If there is a short to voltage condition with the HO2S circuits, the ECM commands open loop for the applicable sensor.
This step tests for a bias voltage across the reference voltage circuit and the low reference circuit of the HO2S. The bias voltage that you are measuring, is the voltage difference between the reference voltage circuit and the low reference circuit. If the reference voltage circuit or the low reference circuit of the HO2S is shorted to a voltage, the bias voltage will be more than the specified value, which indicates there is a condition with the circuits.
This step tests for a short to voltage on the input pumping current circuit and the pump current circuit of the HO2S. The input pumping current circuit and the pump current circuit are connected internally within the ECM. If one of the circuits are shorted to voltage, the other circuit will be affected.
This step isolates if the condition is with the reference voltage circuit or the low reference circuit. If the voltage is less than the specified value, the condition is with low reference circuit.
This step inspects the harness connector for water intrusion, corrosion, and bent or damaged pins.
This step inspects the harness connector for water intrusion, corrosion, and bent or damaged pins.
Step | Action | Values | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Engine Controls Schematics Connector End View Reference: Engine Control Module Connector End Views or Engine Controls Connector End Views | ||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||||||
Does the scan tool display Closed Loop? | -- | Go to Step 3 | Go to Step 4 | |||||||||
3 |
Did the DTC fail this ignition? | -- | Go to Step 4 | Go to Diagnostic Aids | ||||||||
Is the voltage within the specified range? | 350-550 mV | Go to Step 5 | Go to Step 7 | |||||||||
Measure the voltage between the input pump current circuit and a good ground with a DMM. Is the voltage less than the specified value? | 1 V | Go to Step 10 | Go to Step 6 | |||||||||
6 |
Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 12 | ||||||||
Measure the voltage between the reference voltage circuit of the HO2S and a good ground with a DMM. Refer to Circuit Testing . Is the voltage more than the specified value? | 3.5 V | Go to Step 8 | Go to Step 9 | |||||||||
8 | Test the reference voltage circuit of the HO2S for a short to voltage or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 12 | ||||||||
9 | Test the low reference circuit of the HO2S for a short to voltage or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 12 | ||||||||
10 | Test for the following conditions:
Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 11 | ||||||||
Test for shorted terminals and poor connections at the HO2S. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 13 | |||||||||
Test for shorted terminals and poor connections at the ECM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 14 | |||||||||
13 | Replace the HO2S. Refer to Heated Oxygen Sensor 1 Replacement . Did you complete the replacement? | -- | Go to Step 15 | -- | ||||||||
14 | Replace the ECM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 15 | -- | ||||||||
15 |
Did the DTC fail this ignition? | -- | Go to Step 2 | Go to Step 16 | ||||||||
16 | Observe the Capture Info with a scan tool. Are there any DTCs that have not been diagnosed? | -- | System OK |