• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage |
---|---|---|---|
Battery Positive Voltage Circuits | U0100-U0299 | U0100-U0299 | -- |
Ignition Voltage Circuits | U0100-U0299 | U0100-U0299 | -- |
Module Ground Circuits | -- | U0100-U0299 | -- |
Modules connected to the high speed GMLAN serial data circuits monitor for serial data communications during normal vehicle operation. Operating information and commands are exchanged among the modules. The modules have prerecorded information about what messages are needed to be exchanged on the serial data circuits, for each virtual network. The messages are supervised and also, some periodic messages are used by the receiver module as an availability indication of the transmitter module. Each message contains the identification number of the transmitter module.
• | Voltage supplied to the modules is in the normal operating voltage range. |
• | The vehicle power mode requires serial data communication to occur. |
A supervised periodic message that includes the transmitter module availability has not been received.
The module uses a default value for the missing parameter.
• | A current DTC clears when the malfunction is no longer present. |
• | A history DTC clears when the module ignition cycle counter reaches the reset threshold of 50, without a repeat of the malfunction. |
• | A poor connection at the inoperative module may cause this code to set. |
• | An improperly powered module may cause this code to set. |
• | Some modules may not have internal protection for specific voltage outputs and may open a battery positive voltage or ignition voltage source fuse. If a voltage input fuse is open and no short is found in that circuit, ensure that no module output voltage circuit is shorted to ground before replacing the module. |
Master Electrical Component List
⇒ | If the test lamp does not illuminate, repair the circuit for a short to ground or an open/high resistance. If the circuit fuse is open, also test the positive voltage outputs of the module for a short to ground. If the circuits test normal, replace the faulty module. |
⇒ | If the test lamp does not illuminate, repair the circuit for a short to ground or an open/high resistance. If the circuit fuse is open, also test the positive voltage outputs of the module for a short to ground. If the circuits test normal, replace the faulty module. |
⇒ | If greater than 1 ohm, repair the ground circuit for open/high resistance. |
⇒ | If greater than 1 ohm of resistance, test the GMLAN serial data circuit(s) for open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for module replacement, setup, and programming |