Step | Action | Values | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation. | ||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||||||||
2 |
Does the blower motor operate in any of the speed positions? | -- | Go to Step 3 | Go to Blower Motor Inoperative | ||||||||||
3 | Does the blower motor operate at the desired speeds? | -- | Go to Step 4 | Go to Blower Motor Malfunction | ||||||||||
4 | When the A/C is ON, does the customer concern occur? | -- | Go to Step 5 | Go to Step 7 | ||||||||||
5 |
Does the recirculation door move to the recirculation position? | -- | Go to Step 6 | Go to Air Delivery Improper | ||||||||||
6 |
Does the A/C compressor operate? | -- | Go to Step 7 | |||||||||||
7 | Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test . Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 8 | ||||||||||
8 |
Does the air temperature actuator drive shaft rotate at all? | -- | Go to Step 9 | Go to Step 10 | ||||||||||
9 | Inspect the air temperature door and the air temperature actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 10 | ||||||||||
10 | Test the control A and control B circuits of the air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 11 | ||||||||||
11 |
Does the test lamp illuminate with each command? | -- | Go to Step 14 | Go to Step 12 | ||||||||||
12 | Test the ignition 3 voltage circuit of the HVAC control module for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 13 | ||||||||||
13 | Test the ground circuit of the HVAC control module for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 15 | ||||||||||
14 | Inspect for poor connections at the harness connector of the air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 16 | ||||||||||
15 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 18 | Go to Step 17 | ||||||||||
16 | Replace the air temperature actuator. Refer to Temperature Valve Actuator Replacement. Did you complete the replacement? | -- | Go to Step 18 | -- | ||||||||||
17 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 18 | -- | ||||||||||
18 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |