Generator Replacement L26
Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection.
- Remove the drive belt from the generator. Refer to
Drive Belt Replacement.
- Remove the generator rear brace. Refer to
Generator Brace Replacement.
- Remove the bolts (1, 3) and the stud (2) from the generator.
- Disconnect the electrical connector from the generator.
- Position aside the protective boot from the generator output BAT terminal for access.
- Remove the generator output BAT terminal nut and remove the positive battery lead from the generator.
- Remove the generator.
Installation Procedure
- Position the generator to the engine.
Caution: Refer to Fastener Caution in the Preface section.
- Install the positive battery lead to the generator.
- Install the generator output BAT terminal nut.
Tighten
Tighten the generator output BAT terminal nut to 20 N·m (15 lb ft).
- Install the protective boot to the generator output BAT terminal.
- Connect the electrical connector to the generator.
Note: Do not tighten the stud.
- Install the generator stud (2) to the generator bracket.
Note: Do not tighten the bolts.
- Install the generator bolts (1, 3) to the generator bracket.
- Tighten the generator bolts and stud in the order described. The following is a mandatory torque sequence:
Tighten
- Tighten the generator bolt (1) to 50 N·m (37 lb ft).
- Tighten the generator stud (2) to 50 N·m (37 lb ft).
- Tighten the generator rear bracket bolt (3) to 50 N·m (37 lb ft).
- Install the generator rear brace. Refer to
Generator Brace Replacement.
- Install the drive belt. Refer to
Drive Belt Replacement.
- Connect the negative battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection.
Generator Replacement LS4
Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection.
- Remove the engine sight shield. Refer to
Upper Intake Manifold Sight Shield Replacement.
- Remove the drive belt. Refer to
Drive Belt Replacement - Accessory.
- Disconnect the generator electrical connector (2).
- Position aside the protective boot (1) from the generator output BAT terminal for access.
- Remove the generator output BAT terminal nut (4) and remove the positive battery lead (3) from the generator.
- Remove the generator bolts and generator.
Installation Procedure
Caution: Refer to Fastener Caution in the Preface section.
- Install the generator and bolts.
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
- Install the positive battery lead (3) and generator output BAT terminal nut (4) to the generator.
Tighten
Tighten the nut to 20 N·m (15 lb ft).
- Position the protective boot (1) to the generator output BAT terminal.
- Connect the generator electrical connector (2).
- Install the drive belt. Refer to
Drive Belt Replacement - Accessory.
- Install the engine sight shield. Refer to
Upper Intake Manifold Sight Shield Replacement.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection.