Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Check the STOP LAMP fuse. Is the fuse open? | -- | Go to Step 2 | Go to Step 3 |
2 | Repair a short to ground in circuit 140 or circuit 17. Has the repair been made? | -- | -- | |
3 | Using a test light, backprobe between the stop lamp switch harness connector C1 between terminal A and ground. Does the test light illuminate? | -- | Go to Step 4 | Go to Step 7 |
4 |
Does the test light illuminate? | -- | Go to Step 5 | Go to Step 5 |
5 | Repair a poor connection or an open in circuit 17 between the stop lamp switch harness connector C2 terminal B and S205. Has the repair been made? | -- | -- | |
6 | Adjust/Replace the stop lamp switch. Refer to Stop Lamp Switch Adjustment Has the repair been made? | -- | -- | |
7 | Repair a poor connection or and open in circuit 140. Has the repair been made? | -- | -- |