Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Instrument Cluster System Check performed? | -- | Go to Step 2 | |
2 |
Does the Low Washer Fluid indicator illuminate? | -- | Go to Step 3 | |
3 |
Does the Low Washer Fluid indicator illuminate? | -- | Go to Step 4 | Go to Step 5 |
4 | With the J 39200 digital multimeter (DMM) on the ohms scale measure the resistance of CKT 1450 BLK terminal B to ground. Is the resistance within the specified range? | 0-5 ohms | Go to Step 7 | Go to Step 6 |
5 | Locate and repair an open in CKT 99 BLK/WHT. Was a circuit problem found and repaired? | -- | System OK | |
6 | Locate and repair an open in CKT 1450 BLK. Was a circuit problem found and repaired? | -- | System OK | -- |
7 | Replace the windshield washer solvent level switch Rear Window Washer Solvent Container Replacement in Wipers/Washer Systems. Is the replacement complete? | -- | -- |