Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Hydraulic Brake Diagnostic System Check? | Go to Step 2 | |
2 | Turn ON the ignition, with the engine OFF. Did the instrument cluster brake indicator lamp light? | Go to Step 3 | Go to Diagnostic Starting Point - Instrument Panel, Gages and Console |
3 |
Does the brake warning lamp illuminate? | Go to Step 8 | Go to Step 4 |
4 |
Does the scan tool indicate that the park brake switch is active? | Go to Step 7 | Go to Step 5 |
5 | Inspect circuit 1830 for an open or high resistance. Did you find and correct the condition? | System OK | Go to Step 6 |
6 | Replace park brake indicator switch. Is the repair complete? | System OK | -- |
7 | Using a scan tool, establish communication with the instrument panel cluster. Can communication be established with the instrument panel cluster? | Go to Diagnostic Starting Point in Body Control System | Go to Diagnostic Starting Point - Instrument Panel, Gages and Console in Instrument Panel, Gauges and Console |
8 |
Does the brake warning indicator lamp light? | Go to Step 9 | Go to Step 12 |
9 | Jumper a 3A fused jumper wire between the brake fluid level indicator harness connector A and B. Does the brake warning indicator lamp illuminate? | Go to Step 10 | Go to Step 11 |
10 | Replace the brake fluid level indicator switch. Is the repair complete? | System OK | -- |
11 | Repair the open or high resistance in circuit 1550. Is the repair complete? | System OK | -- |
12 | Inspect circuit 209 for an open or high resistance. Was there a open or high resistance on circuit 209? | Go to Step 13 | Go to Step 14 |
13 | Repair the open or high resistance in circuit 209. Is the repair complete? | System OK | -- |
14 | Replace instrument panel cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | System OK | -- |