Tools Required
J 34094-A
Thermo Element Height Gage
Removal Procedure
- Remove the oil pan. Refer to
Oil Pan Replacement
.
- Remove the thermo element pins and washers (120 and 123).
- Remove the thermo element (121) and the thermo element plate (122).
Installation Procedure
- Use the
J 34094-A
to set the middle thermo pin (123).
- Install the new thermo element plate (122).
- Install the pin and washer (120).
- Use the
J 34094-A
to set the height of the pin and washer (120) furthest from the accumulator.
- Use the
J 34094-A
to set the height of the second pin and washer (120).
- Carefully install the thermo element (121) between the two pin and washers (120). The V in the thermo element
(121) must contact the thermo element plate (122).
- Install the oil pan. Refer to
Oil Pan Replacement
.
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will
need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
- Reset the TAP values. Refer to
Adapt Function
.