Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the HVAC system operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Inspect the fuse block for an open in the HVAC HI fuse. Is the HVAC HI fuse open? | -- | Go to Step 3 | Go to Step 6 |
3 |
Does the test lamp light ? | -- | Go to Step 5 | Go to Step 4 |
4 | Locate and repair a short to ground in CKT 40 (ORN). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 10 | -- |
5 |
Does the test lamp light ? | -- | Go to Step 6 | Go to Step 7 |
6 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | Go to Step 10 | -- |
7 |
Is there an open or short to ground in CKT 52 (ORN)? | -- | Go to Step 8 | Go to Step 9 |
8 | Locate and repair the open or the short to ground in CKT 52 (ORN). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 10 | -- |
9 | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete? | -- | Go to Step 10 | -- |
10 | Verify that the system operates properly. Does the system operate properly? | -- | System OK | Go to Symptoms |