Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the HVAC system operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | Go to Step 3 | -- |
3 | Verify that the system operates properly. Does the system operate properly? | -- | System OK | Go to Symptoms |