GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Remove the HVAC control module. Refer to HVAC Module Assembly Replacement .
  2. Remove all of the outer HVAC control module seals.
  3. Remove the recirculation housing.
  4. Unclip the heater/defrost actuator from the HVAC control module.
  5. Remove the heater/defrost actuator.

  6. Remove the HVAC control module case upper screws.

  7. Object Number: 295357  Size: SH
  8. Separate the HVAC control module case (1).

  9. Object Number: 296253  Size: SH
  10. Remove the HVAC control module seal (2) from the lower case (1).

  11. Object Number: 295362  Size: SH
  12. Remove the evaporator core.

  13. Object Number: 144107  Size: SH
  14. Remove and discard the evaporator core lower seals.

  15. Object Number: 144104  Size: SH
  16. Remove and discard the evaporator core upper seal.

  17. Object Number: 144106  Size: SH
  18. Remove and discard the evaporator core side seal.

  19. Object Number: 144102  Size: SH
  20. Remove and discard the water core filter.

Installation Procedure


    Object Number: 144102  Size: SH
  1. Install the new evaporator core seal to the evaporator core.

  2. Object Number: 144106  Size: SH
  3. Install a new side seal to the evaporator core.

  4. Object Number: 144104  Size: SH
  5. Install a new upper seal to the evaporator core.

  6. Object Number: 144107  Size: SH
  7. Install two new lower seals to the evaporator core.

  8. Object Number: 296253  Size: SH
  9. Install the HVAC control module seal (2) to the lower control module case (1).

  10. Object Number: 295362  Size: SH
  11. Install the evaporator core into the HVAC control module lower case.

  12. Object Number: 295357  Size: SH
  13. Align retaining clip (1) and install the upper and lower HVAC mode case.
  14. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  15. Install the HVAC control module case upper screws.
  16. Tighten
    Tighten the HVAC control module case screws to 1.5 N·m (13 lb in).

  17. Install the heater/defrost actuator to the HVAC control module.
  18. Install the recirculation housing.
  19. Tighten
    Tighten the recirculation housing screws to 1.5 N·m (13 lb in).