Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Master Electrical Component List in Wiring Systems | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Are the fog lamps off? | Go to Step 3 | Go to Step 4 |
3 |
Are the fog lamps off? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 9 |
4 | Remove the fog lamp relay. Do the fog lamps turn off? | Go to Step 5 | Go to Step 7 |
5 | Connect a test lamp between the coil side supply of the fog lamp relay and the control circuit of the fog lamp relay. Does the test lamp illuminate? | Go to Step 6 | Go to Step 11 |
6 |
Is the test lamp illuminated? | Go to Step 8 | Go to Step 10 |
7 | Test for a short to battery positive voltage in the fog lamp supply voltage circuit and the fog lamp indicator supply voltage circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
8 | Repair a short to ground in the control circuit of the fog lamp relay. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Has the repair been made? | Go to Step 13 | -- |
9 | Repair a short to ground in the fog lamp enable circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Has the repair been made? | Go to Step 13 | -- |
10 | Replace the fog lamp switch. Refer to Fog Lamp Switch Replacement . Has the repair been made? | Go to Step 13 | -- |
11 | Replace the fog lamp relay. Refer to Relay Replacement in Wiring Systems. Has the repair been made? | Go to Step 13 | -- |
12 | Replace the fuse block - underhood. Refer to Underhood Electrical Center or Junction Block Replacement in Wiring Systems. Has the repair been made? | Go to Step 13 | -- |
13 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |