Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Is the blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On |
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any of the speed positions? | Go to Step 4 | Go to Blower Motor Inoperative |
4 | Place the blower motor switch in each speed position. Does the blower motor operate at the desired speeds? | Go to Step 5 | Go to Blower Motor Malfunction |
5 |
Does the recirculation door move to the recirculation position? | Go to Step 6 | |
6 | Place the mode switch in each mode position. Does the air flow from the proper air distribution outlets in each mode position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |