Removal Procedure
- Remove the instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel,
Gages, and Console.
- Remove the instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel,
Gages, and Console.
- Disconnect the vacuum
hoses from the vacuum tank.
- Remove the screws that
secure the vacuum tank to the HVAC module.
- Remove the vacuum tank.
Installation Procedure
- Install the vacuum tank
to the HVAC control module.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the vacuum tank.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the vacuum hoses
to the vacuum tank.
- Install the instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel,
Gages, and Console.
- Install the instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in
Instrument Panel, Gages, and Console.