Table 1: | Heating and Air Conditioning Scan Tool Output Controls |
Table 2: | PCM Scan Tool Output Controls |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
Blower Motor | Miscellaneous Test | The scan tool displays Off or On selections. This function allows you to command the blower motor on at full speed or off. |
Left Mix Motor | Miscellaneous Test | The scan tool displays Off or On selections. Selecting Off allows you to command the motor to its minimum (cold) position. Selecting On allows you to command the motor to its maximum (hot) position. |
Right Mix Motor | Miscellaneous Test | The scan tool displays Off or On selections. Selecting Off allows you to command the motor to its minimum (hot) position. Selecting On allows you to command the motor to its maximum (cold) position. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
A/C Relay | Engine Output Controls | The scan tool displays ON or OFF selections. This command allows you to turn the A/C relay On or Off for 5 seconds. When the A/C relay is commanded On, the A/C compressor clutch should be engaged. |