The numbers below refer to the step numbers on the diagnostic table.
Lack of communication may be due to a partial malfunction of the class 2 serial data circuit or due to a total malfunction of the class 2 serial data circuit. The specified procedure will determine the particular condition.
The presence of DTCs which begin with "U" indicate some other module is not communicating. The specified procedure will compile all the available information before tests are performed.
Step | Action | Yes | No |
---|---|---|---|
1 | Install a scan tool. Does the scan tool power up? | Go to Step 2 | Go to Scan Tool Does Not Power Up in Data Link Communications |
Does the scan tool communicate with the body control module? | Go to Step 3 | Go to Scan Tool Does Not Communicate with Class 2 Device in Data Link Communications | |
3 | Select the body control module display DTCs function on the scan tool. Does the scan tool display any DTCs? | Go to Step 4 | Go to Step 7 |
Does the scan tool display any DTCs which begin with a "U"? | Go to Diagnostic Trouble Code (DTC) List in Data Link Communications | Go to Step 5 | |
5 | Does the scan tool display DTC B1000, B1013, B1334, B1339, B1354 or B1422? | Go to Diagnostic Trouble Code (DTC) List in Body Control System | Go to Step 6 |
6 | Does the scan tool display DTC B1477 or 1478? | Go to Step 7 | |
7 | Check the Courtesy Lamps for proper operation. Refer to Interior Lighting Systems Description and Operation in Lighting System. Do the Courtesy Lamps operate properly? | Go to Symptoms - Lighting Systems in Lighting System |