Removal Procedure
- Remove the instrument panel accessory trim plate. Refer to
Instrument Panel Accessory Trim Plate Replacement
in Instrument Panel, Gages and Console.
- Remove the screws from the HVAC control
module.
- Disconnect the electrical connectors from the HVAC control module.
- Disconnect the vacuum connectors from the HVAC control vacuum valve.
- Remove the HVAC control module from the instrument panel.
- Remove the vacuum valve from the HVAC control module.
Installation Procedure
- Install the vacuum valve to the HVAC control module.
- Connect the electrical connectors
to the HVAC control module.
- Connect the vacuum connectors to the HVAC control vacuum valve.
- Install the HVAC control module to the instrument panel.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the HVAC control module.
Tighten
Tighten the screws to 2 N·m (18 lb ft).
- Install the instrument panel accessory trim plate. Refer to
Instrument Panel Accessory Trim Plate Replacement
in Instrument Panel, Gages and Console.