Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the engine oil pressure switch to 16 N·m (12 lb ft).
Tighten
Tighten the camshaft position sensor bolt to 10 N·m (89 lb in).
Tighten
Tighten the crankshaft position sensor stud to 11 N·m (98 lb in).
Tighten
Tighten the knock sensor to 19 N·m (14 lb ft).
Tighten
Tighten the oil gallery plug (1) to 19 N·m (14 lb ft).
Tighten
Tighten the oil gallery plug (2) to 33 N·m (24 lb ft).
Tighten
Tighten the oil gallery plugs (1 and 4) to 19 N·m (14 lb ft).
Tighten
Tighten the oil gallery plugs (2 and 3) to 33 N·m (24 lb ft).
Tighten
Tighten the coolant drain plug to 19 N·m (14 lb ft).
Tighten
Tighten the coolant drain plug to 19 N·m (14 lb ft).