Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Inspect the fuse K1-K3 in the fuse block. Is the fuse open? | -- | Go to Step 2 | Go to Step 5 |
2 | Inspect for a short to ground in circuit 40. Is there a short to ground in circuit 40? | -- | Go to Step 3 | Go to Step 4 |
3 | Repair a short to ground in circuit 40. Is the repair complete? | -- | -- | |
4 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | -- | |
5 |
Does the test light illuminate? | -- | Go to Step 6 | Go to Step 10 |
6 |
Does the test light illuminate? | -- | Go to Step 4 | Go to Step 7 |
7 |
Is there a poor connection, an open or a short to ground in circuit 52? | -- | Go to Step 8 | Go to Step 9 |
8 | Repair the fault in circuit 52. Is the repair complete? | -- | -- | |
9 | Replace the HVAC control assembly. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- | |
10 | Repair a poor connection or an open in circuit 40. Is the repair complete? | -- | -- |