Temperature Actuator Replacement LH
Removal Procedure
- Remove the left instrument panel insulator.
Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gauges
and Console.
- Remove the knee bolster. Refer to
Knee Bolster Replacement
in Instrument Panel, Gauges and Console.
- Disconnect the electrical
connector from the temperature valve electric actuator.
- Remove the mounting bolts from the temperature valve electric
actuator.
- Remove the temperature
valve electric actuator.
Installation Procedure
- Position the temperature
valve electric actuator, then align the slots in the electric actuator driver
to the flats on the temperature valve shaft.
- Slide the electric actuator driver onto the shaft, while aligning the
actuator locating hole to the forward alignment pin on the HVAC module
case. The actuator driver should completely seat onto the temperature
valve shaft and the mounting holes should be flush with the mounting
bosses on the HVAC module case.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the mounting
screws to the temperature valve electric actuator.
Tighten
Tighten the temperature actuator bolts to 1.5 N·m (13 lb in).
- Connect the electrical
connector to the temperature valve electric actuator.
- Install the knee bolster. Refer to
Knee Bolster Replacement
in
Instrument Panel, Gauges and Console.
- Install the
left instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in
Instrument Panel, Gauges and Console.
Temperature Actuator Replacement RH
Removal Procedure
- Remove the right side instrument panel
insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel,
Gauges and Console.
- Remove the instrument panel compartment.
Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gauges
and Console.
- Disconnect the electrical
connector from the RH temperature valve electric actuator.
- Remove the bolts retaining the RH temperature valve electric actuator.
- Remove the electric actuator.
Installation Procedure
- Position the temperature valve electric actuator, then align the slots
in the electric actuator driver to the flats on the temperature
valve shaft.
- Slide the electric actuator driver onto
the shaft, while aligning the actuator locating holes to the forward alignment
pin on the HVAC module case. The actuator driver should completely
seat onto the temperature valve shaft and the mounting holes should
be flush with the mounting bosses on the HVAC module case.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the bolts
to the temperature valve electric actuator.
Tighten
Tighten the temperature actuator bolts to 1.5 N·m (13 lb in).
- Connect the electrical
connector to the temperature valve electric actuator.
- Install the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in
Instrument Panel, Gauges and Console.
- Install the
right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in
Instrument Panel, Gauges and Console.