Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the test light illuminate? | -- | Go to Step 3 | Go to Step 2 |
2 | Repair a poor connection or an open in circuit 8 between S203 and the inoperable component. Is the repair complete? | -- | -- | |
3 | Using a test light, backprobe the inoperable lamp harness connector between circuit 8 and ground (circuit 750, 1450 or 1750). Does the test light illuminate? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair a poor connection or an open in the ground circuit between the inoperable component (circuit 750, 1450 or 1750) and G200, G201, G203, or G301. Is the repair complete? | -- | -- | |
5 | Replace the bulb/inoperable component. Is the repair complete? | -- | -- |