Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Instrument Cluster Diagnostic System Check performed? | -- | Go to Step 2 | |
2 |
Does the Low Washer Fluid indicator turn off? | -- | Go to Step 3 | Go to Step 7 |
3 |
Is the resistance equal to the specified value? | ∞ | Go to Step 4 | Go to Step 5 |
4 | Using the DMM on the ohms scale, measure the resistance across the windshield washer solvent level switch terminals. Is the resistance equal to the specified value? | ∞ | System OK | Go to Step 6 |
5 | Locate and repair an short to ground in circuit 99 (BLK/WHT). Is the repair complete? | -- | -- | |
6 | Replace the windshield washer solvent level switch. Refer to Windshield Washer Solvent Container Replacement . Is the repair complete? | -- | -- | |
7 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the repair complete? | -- | -- |