The instrument cluster receives voltage inputs from 3 ignition signals. The instrument cluster receives voltage from the IGN 01 fuse when the ignition switch is in the off position, the accessory position, the on position or the start position. The instrument cluster receives voltage from the CLUSTER fuse when the ignition switch is in the on position and the start position. The instrument cluster receives voltage from the CRANK SIGNAL fuse when the ignition switch is in the START position. If the instrument cluster does not receive any of the following voltage input combinations, a malfunction is present and this DTC sets:
• | If circuit 39 is active and circuit 1500 is inactive |
• | If circuit 806 is active and circuit 1500 is inactive |
• | If circuit 806 is active and circuit 39 is inactive |
• | The instrument cluster does not detect voltage from circuit 1500 when the ignition switch is in the accessory, on or start positions, but the instrument cluster detects voltage in circuit 39 when the ignition switch is in the on position or the start position. |
• | The instrument cluster detects voltage in circuit 806 when the ignition switch is in the start position, but the instrument cluster does not detect voltage in circuit 1500 when the ignition switch is in the accessory, on or start positions. |
• | The instrument cluster detects voltage in circuit 806 when the ignition switch is in the start position, but the instrument cluster does not detect voltage in circuit 39 when the ignition switch is in the on or start positions. |
• | All conditions must be present for more than 0.3 seconds. |
• | The instrument cluster stores DTC B0608 in memory. |
• | The SERVICE VEHICLE SOON indicator turns on. |
• | Under all fault conditions the ignition switch must be cycled from on to off, back to on before this DTC can change from current to history. |
• | The instrument cluster no longer detects an open or short to B+ in circuit 39, circuit 806, and circuit 1500. |
• | A history DTC will clear after 100 drive cycles if the condition for this DTC is no longer present. |
• | Use a scan tool. |
The following conditions may cause an intermittent malfunction to occur:
• | An intermittent open or short to voltage in circuit 39, circuit 806, or circuit 1500. |
• | Poor connections at the instrument cluster or fuse block |
• | The instrument cluster is always detecting B+ from one or more of these 3 inputs. |
• | The instrument cluster is never recognizing B+ from circuit 39, circuit 806, or circuit 1500. |
The numbers below refer to the step numbers on the diagnostic table.
Always perform the Instrument Cluster Diagnostic System Check before attempting to diagnose DTC B0608.
This test will determine if there is a short to B+ in circuit 39.
This test checks for an open in circuit 39.
This test will determine if there is a short to B+ in circuit 806.
This test checks for an open in circuit 806.
This test will determine if there is a short to B+ in circuit 1500.
This test checks for an open in circuit 1500.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Was the Instrument Cluster Diagnostic System Check performed? | -- | Go to Step 2 | ||
Does the test light stay off? | -- | Go to Step 4 | Go to Step 3 | |
3 | Repair a short to B+ in circuit 39. Is the repair complete? | -- | Go to Step 15 | -- |
Is the test light on? | -- | Go to Step 5 | Go to Step 6 | |
Does the test light stay off? | -- | Go to Step 8 | Go to Step 7 | |
6 | Repair a poor connection or an open in circuit 39 between the instrument cluster harness connector terminal B12 and the fuse block terminal D6. Is the repair complete? | -- | Go to Step 15 | -- |
7 | Repair a short to B+ in circuit 806. Is the repair complete? | -- | Go to Step 15 | -- |
Upon turning the ignition switch to the start position, did the test light turn on? | -- | Go to Step 9 | Go to Step 10 | |
Does the test light stay off? | -- | Go to Step 11 | Go to Step 12 | |
10 | Repair a poor connection or an open in circuit 806 between the instrument cluster harness connector terminal A6 and the fuse block terminal A4. Is the repair complete? | -- | Go to Step 15 | -- |
Did the test light turn on when the ignition switch was in the accessory, on and start positions? | -- | Go to Step 13 | Go to Step 14 | |
12 | Repair a short to B+ in circuit 1500. Is the repair complete? | -- | Go to Step 15 | -- |
13 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the repair complete? | -- | Go to Step 15 | -- |
14 | Repair a poor connection or an open in circuit 1500. Is the repair complete? | -- | Go to Step 15 | -- |
15 |
Are there any DTCs stored in the instrument cluster? | -- | System OK |