• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Washer Fluid Level Sensor Signal | 2 | 1 | 1 | -- |
Washer Fluid Level Sensor Ground | -- | 1 | 1 | -- |
1. Low Washer Fluid Indicator Inoperative 2. Low Washer Indicator Always On |
The instrument panel cluster (IPC) monitors the washer fluid level sensor via the washer fluid level sensor signal circuit. With the switch closed, the signal circuit is pulled to ground indicating low fluid level. When low fluid level is indicated, the IPC will illuminate the low washer fluid indicator.
Wiper/Washer System Description and Operation
Control Module References for scan tool information
⇒ | If not above the minimum level, fill the reservoir and inspect for leaks. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal 2 for a short to ground. If the circuit tests normal, replace the IPC. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the IPC. |
⇒ | If not the specified value, replace the washer fluid level sensor. |
⇒ | If not within the specified range, replace the washer fluid level sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for IPC replacement, setup, and programming |