Removal Procedure
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.
- Disconnect the engine wiring harness electrical connector (4) from the mass air flow (MAF)/intake air temperature (IAT) sensor.
- Remove the MAF/IAT sensor screws (1).
- Remove the MAF/IAT sensor (2) from the air cleaner assembly.
- Remove the MAF/IAT sensor seal (3).
Installation Procedure
- Install the MAF/IAT sensor seal (3) onto the MAF/IAT sensor.
- Install the MAF/IAT sensor (2) to the air cleaner assembly.
Notice: Refer to Fastener Notice in the Preface section.
- Install the MAF/IAT sensor screws (1).
Tighten
Tighten the screws to 4 N·m (35 lb in).
- Connect the engine wiring harness electrical connector (4) to the MAF/IAT sensor.
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.