GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC P0621: Generator L-Terminal Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

B+

P0622

P0622

--

--

Field Duty Cycle Signal

P0622

P0622

--

--

Turn On Signal

P0621

--

P0621

--

Typical Scan Tool Data

GEN L-Terminal Ckt Short Gnd Test Status - ECM

Circuit

Short to Ground

Open

Short to Voltage

Operating Conditions: Engine running.

Parameter Normal Value: OK

Turn On Signal

Fault

OK

Not Run


GEN L-Terminal Ckt Short Volts Test Status - ECM

Circuit

Short to Ground

Open

Short to Voltage

Operating Conditions: Engine running.

Parameter Normal Value: OK

Turn On Signal

Not Run

OK

Fault

Circuit/System Description

The engine control module (ECM) uses the generator turn on signal circuit, or L-terminal circuit, to control the load of the generator on the engine. A high side driver in the ECM applies a voltage to the voltage regulator. This signals the voltage regulator to turn the field circuit ON and OFF. The ECM monitors the state of the generator turn ON signal circuit. The ECM should detect low voltage on generator turn on signal circuit when the ignition is ON and the engine is OFF, or when the charging system malfunctions. With the engine running, the ECM should detect high voltage on the generator turn on signal circuit.

Conditions for Running the DTC

The engine is running.

Conditions for Setting the DTC

The ECM detects low voltage on the generator turn on signal circuit for 15 seconds.

Action Taken When the DTC Sets

    • The charge indicator turns ON.
    • The driver information center (DIC) displays the SERVICE BATTERY CHARGING SYSTEM message.

Conditions for Clearing the DTC

    • The DTC passes when condition for setting the DTC is no longer present.
    • The charge indicator and DIC message turn OFF when the DTC passes.

Reference Information

Schematic Reference

Starting and Charging Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Charging System Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

Engine running, observing the following scan tool ECM circuit status parameters.

    • GEN L-Terminal Ckt Short Gnd Test Status
    • GEN L-Terminal Ckt Short Volts Test Status

The reading for each parameter should be OK.

Circuit/System Testing

  1. Ignition OFF, disconnect the X1 harness connector at the generator.
  2. Ignition ON, test for less than 1 V between the generator turn on signal circuit terminal 1 and ground.
  3. If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the ECM.
  4. Engine Running, command the GEN-L Terminal circuit ON to 85% with a scan tool. Test for greater than 3.5 V between the signal circuit terminal 1 and ground.
  5. If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
  6. If all circuits test normal, test or replace the generator.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Generator Replacement
    •  Control Module References for ECM replacement, setup, and programming.