Removal Procedure
Notice: To prevent equipment damage, never connect or disconnect the wiring
harness connection from the EBCM with the ignition switch in the ON
position.
- Turn the ignition switch to the OFF position.
- Remove the air cleaner housing from the engine compartment. Refer to
Air Cleaner Assembly Replacement
in Engine Controls.
- Remove red locking tab from connector lock tab (1).
- Push down lock tab (1) and then move sliding connector cover (2) to the open position.
- Disconnect the EBCM harness connector.
- Brush off any dirt/debris that has accumulated on the assembly.
- Remove the four EBCM to BPMV screws.
Important: Do not pry apart using a tool. Be careful not to damage BPMV surface. Care must be taken not to damage the solenoid valves when the EBCM is removed from the BPMV.
- Separate the EBCM from the BPMV by gently pulling apart until separated.
Installation Procedure
- Clean the BPMV surface with alcohol using a clean rag.
- Install the EBCM to the BPMV.
- Install the four screws that attaches the EBCM to BPMV.
Tighten
Tighten the four screws to 5 N·m (44 lb. in).
- Connect the EBCM harness connector.
- Push down lock tab (1) and then move sliding connector cover (2) back in the home position to lock.
- Insert red locking tab back in place.
- Install the air cleaner housing. Refer to
Air Cleaner Assembly Replacement
in Engine Controls.
- Turn the ignition switch to the RUN position, do not start engine.
- Perform the
Diagnostic System Check - ABS
.