Table 1: | A/C Performance Table |
The following test measures the A/C system operating efficiency by comparing:
• | The ambient air temperature |
• | The ambient air humidity |
• | The pressure at the high-pressure side of the refrigeration system |
• | The pressure at the low-pressure side of the refrigeration system |
• | The temperature of the air being discharged into the passenger compartment |
The number(s) below refer to the step number(s) on the diagnostic table.
This step determines if there is enough refrigerant in the A/C system to operate it without damage.
This step determines if the A/C compressor is operating.
This step measures the performance of the A/C system.
This step allows for vehicle variations as well as high ambient temperatures.
Step | Action | Value(s) | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
The low and high side pressure readings should be almost equal to each other once the system has come to rest. Are both the low and high side pressures above the specified value ? | 345 kPa (50 psi) | Go to Leak Testing | ||||||||||||||||||||||||
Does the compressor clutch engage ? | -- | |||||||||||||||||||||||||
Important: Record the relative humidity and the ambient temperature AT THE TIME OF THE TEST.
Does all the data recorded fall within the specified ranges of the table below? | -- | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | |||||||||||||||||||||||||
5 | Compare the recorded pressures to the A/C System Pressure - Zone Classification Chart below. Do both the low and high side pressures fall within Zone A on the chart ? | -- | Go to Cooling Insufficient - Air Conditioning (A/C) System - Pressure Zone A | |||||||||||||||||||||||
6 | Do the pressures fall within Zone B ? | -- | Go to Cooling Insufficient - Air Conditioning (A/C) System - Pressure Zone B | |||||||||||||||||||||||
7 | Do the pressures fall within Zone C ? | -- | Go to Cooling Insufficient - Air Conditioning (A/C) System - Pressure Zone C | |||||||||||||||||||||||
8 | Do the pressures fall within Zone D ? | -- | Go to Cooling Insufficient - Air Conditioning (A/C) System - Pressure Zone D | |||||||||||||||||||||||
9 | Operate the system in order to verify the repair. Did you correct the condition ? | -- | System OK | Go to Symptoms in HVAC System - Manual |
Relative Humidity | Ambient Air Temp | Low Side Pressure | Engine Speed | High Side Pressure | Center Air Outlet Temp Front System | Center Air Outlet Temp Rear System | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
°C | °F | kPa | psi | kPa | psi | °C | °F | °C | °F | ||
Important: This table is to be used in conjunction with the appropriate diagnostic table(s). | |||||||||||
20% | 27 | 80 | 186-228¹ | 27-33¹ | 2000 RPM | 1496- 1538¹ | 217-223¹ | 10¹ | 50¹ | 11¹ | 51¹ |
32 | 90 | 200-241 | 29-35 | 1703- 1744 | 247-253 | 12 | 53 | 12 | 53 | ||
38 | 100 | 241-283 | 35-41 | 2186- 2227 | 317-323 | 14 | 58 | 16 | 60 | ||
30% | 20 | 70 | 186-228¹ | 27-33¹ | 2000 RPM | 1496-1538¹ | 217-223¹ | 10¹ | 50¹ | 11 | 51 |
27 | 80 | 221-262 | 32-38 | 1772- 1813 | 257-263 | 13 | 56 | 13 | 56 | ||
32 | 90 | 241-283 | 35-41 | 2144-2186 | 311-317 | 15 | 59 | 16 | 60 | ||
38 | 100 | 290-331 | 42-48 | 2496-2537 | 362-368 | 18 | 64 | 18 | 64 | ||
40% | 21 | 70 | 186-228¹ | 27-33¹ | 2000 RPM | 1496-1538¹ | 217-223¹ | 11¹ | 51¹ | 11 | 51 |
27 | 80 | 248-290¹ | 36-42¹ | 2048-2089¹ | 297-303¹ | 15¹ | 59¹ | 15 | 50 | ||
32 | 90 | 2 76-317 | 40-46 | 2427-2468 | 352-358 | 18 | 65 | 18 | 65 | ||
38 | 100 | 338-379 | 49-55 | 2668-2710 | 387-393 | 22 | 72 | 22 | 72 | ||
50% | 21 | 70 | 207-248¹ | 30-36¹ | 2000 RPM | 1807-1848¹ | 262-268¹ | 13¹ | 55¹ | 13 | 55 |
27 | 80 | 269-310 | 39-45 | 2193-2234 | 318-324 | 17 | 63 | 17 | 63 | ||
32 | 90 | 290-331 | 42-48 | 2462-2503 | 357-363 | 21 | 70 | 21 | 70 | ||
38 | 100 | 352-393 | 51-57 | 2703-2744 | 392-398 | 24 | 76 | 24 | 76 | ||
60% | 21 | 70 | 221-262¹ | 32-38¹ | 2000 RPM | 1875-1917¹ | 272-278¹ | 13¹ | 55¹ | 13 | 55 |
27 | 80 | 269-310¹ | 39-45¹ | 2220-2262¹ | 322-328¹ | 16¹ | 60¹ | 16 | 60 | ||
32 | 90 | 297-338 | 43-49 | 2462-2503 | 357-363 | 18 | 64 | 18 | 64 | ||
38 | 100 | 359-400 | 52-58 | 2703-2744 | 392-398 | 22 | 71 | 23 | 73 | ||
70% | 21 | 70 | 228-269¹ | 33-39¹ | 2000 RPM | 1910-1951¹ | 277-283¹ | 11¹ | 51¹ | 11 | 51 |
27 | 80 | 276-317¹ | 40-46¹ | 2324-2365¹ | 337-343¹ | 14¹ | 58¹ | 15 | 59 | ||
32 | 90 | 310-352 | 45-51 | 2462-2503 | 357-363 | 18 | 65 | 19 | 67 | ||
38 | 100 | 359-400 | 52-58 | 2737-2779 | 397-403 | 23 | 74 | 23 | 74 | ||
80% | 21 | 70 | 290-331¹ | 42-48¹ | 2000 RPM | 1944-1986¹ | 282-288¹ | 10¹ | 50¹ | 11 | 51 |
27 | 80 | 310-352 | 45-51 | 2358-2400 | 342-348 | 13 | 56 | 14 | 58 | ||
32 | 90 | 338 | 49 | 2462-2503 | 357-363 | 19 | 67 | 21 | 69 | ||
90% | 21 | 70 | 241-283¹ | 35-41¹ | 2000 RPM | 1979-2020¹ | 287-293¹ | 15¹ | 59¹ | 16 | 60 |
27 | 80 | 317-359 | 46-52 | 2393-2434 | 347-353 | 16 | 61 | 17 | 62 | ||
¹ This data reflects the performance obtained while the engine cooling fans were operating in series (low speed), rather than in parallel (high speed). |