Step
| Action
| Value(s)
| Yes
| No
|
DEFINITION: Noise originating from the blower motor and/or the air delivery
system. No loss of battery or ground is occuring in the blower motor circuit.
The blower motor resistor and the blower motor are not exhibiting any
intermittent internal shorts. For electrical diagnosis of the blower motor
circuit, refer to
Blower Motor Inoperative at Any Speed
in HVAC Systems -- Manual.
|
1
| Were you sent here
from the HVAC System Check?
| --
|
Go to Step
2
| Go to
Control Assembly Description
in HVAC Systems -- Manual
|
2
|
- Sit inside the vehicle.
- Close the vehicle doors and windows.
- Turn the ignition switch to ON; engine OFF.
- Turn the blower switch to position 5 (high).
- Set the temperature control to full cold.
- Set the mode control to UPPER (I/P outlets).
- Cycle through all the blower motor speeds, modes (including outside
air and recirc) and temperature control positions to determine where noise
occurs and where noise does not occur.
- Attempt to define the type of noise:
• | Tick/click, chirping, groaning, scraping |
Is a scrape or pop noise evident when selecting modes or temperature
settings (moving a mode or temperature valve)?
| --
|
Go to Step 12
|
Go to Step
3
|
3
| Is a tick/click, chirping, groaning or scraping noise present
-- constantly but decreases as blower motor speed is decreased, or only
at start-up/intermttent -- in all modes?
| --
|
Go to Step 6
|
Go to Step
4
|
4
| Is an air rush/whistle noise evident in all modes but not
all temperature settings?
| --
|
Go to Step
13
|
Go to Step 5
|
5
| Is an air rush/whistle noise evident only in defrost or lower mode?
| --
|
Go to Step 14
|
Go to Step 15
|
6
| Check for
blower motor and impeller assembly excessive vibration at each blower motor
speed by feeling the blower case.
Is excessive vibration present?
| --
|
Go to Step
7
|
Go to Step 9
|
7
|
- Remove the blower motor (w/impeller). Refer to
Blower Motor and Fan Replacement
.
- Examine the blower motor impeller for the following conditions:
• | Deposits of foreign material |
• | Loose impeller retainer |
• | Improper impeller alignment |
Does the blower motor impeller exhibit any of these abnormal conditions?
| --
|
Go to Step 8
|
Go to Step 9
|
8
|
- Repair or replace the blower motor impeller.
- Install the blower motor and impeller assembly. Refer to
Blower Motor and Fan Replacement
.
Is the action complete?
| --
|
Go to Step
16
| --
|
9
|
- Remove the blower motor (w/impeller). Refer to
Blower Motor and Fan Replacement
.
- Check for the presence of foreign material at the opening of the
blower intake.
Was foreign material found?
| --
|
Go to Step
11
|
Go to Step 10
|
10
|
- Replace the blower motor.
- Install the blower motor and impeller assembly. Refer to
Blower Motor and Fan Replacement
.
Is the repair complete?
| --
|
Go to Step
17
| --
|
11
|
- Remove the foreign material from the blower case.
- Repair as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
12
|
- Remove the I/P upper trim pad. Refer to
Instrument Panel Trim Pad Replacement
in Instrument Panel, Gauges
and Console.
- Check the defroster, mode, air inlet and temperature valve function.
- Repair or replace as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
13
|
- Remove the I/P upper trim pad. Refer to
Instrument Panel Trim Pad Replacement
in Instrument Panel, Gauges
and Console.
- Check the temperature valve seals.
- Repair or replace as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
14
|
- Remove the I/P upper trim pad. Refer to
Instrument Panel Trim Pad Replacement
in Instrument Panel, Gauges
and Console.
- Check the ducts for obstructions or foreign materials.
- Remove any obstructions or foreign material found.
- Check the defroster valve function.
- Repair or replace as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
15
|
- Remove the I/P upper trim pad. Refer to
Instrument Panel Trim Pad Replacement
in Instrument Panel, Gauges
and Console.
- Check the ducts for obstructions or foreign materials.
- Remove any obstructions or foreign material found.
- Check the defroster valve seals.
- Repair or replace as necessary.
Is the action complete?
| --
|
Go to Step
17
| --
|
16
|
- Turn OFF the ignition switch.
- Reconnect or install any connectors or components which were disconnected
or removed.
- Recheck for the presence of blower motor/air delivery system noise.
Is the noise still present?
| --
|
Go to Step
10
| Go to
Control Assembly Description
in HVAC Systems -- Manual
|
17
|
- Turn OFF the ignition switch.
- Reconnect or install any connectors or components which were disconnected
or removed.
- Recheck for the presence of blower motor/air delivery system noise.
Is the noise still present?
| --
|
Go to Step
2
| Go to
Control Assembly Description
in HVAC Systems -- Manual
|