Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the Blower Controls Circuit Description and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify that the front blower motor operates at high speed only. Does the front blower motor operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is the test lamp on? | -- | Go to Step 4 | Go to Step 5 |
4 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete? | -- | Go to Step 6 | -- |
5 | Replace the heater-A/C control. Refer to HVAC Module Assembly Replacement . Is the repair complete? | -- | Go to Step 6 | -- |
6 |
Did you correct the condition? | -- | System OK | Go to Step 3 |