• | Heat Gun - capable of 260°C (500°F) |
• | Test lamp |
• | Rear Window Defogger Repair Kit GM P/N 12346001 or the equivalent |
Caution: To avoid personal injury:
• Do not allow the repair material to come in contact with skin
or eyes and avoid breathing vapors. • Do not use near sparks or open flame.
Caution: When working with any type of glass or sheet metal with exposed or rough edges, wear approved safety glasses and gloves in order to reduce the chance of personal injury.
Important:
• Ensure that the grid line repair material is not beyond the expiration
date. • Use the repair decal or tape in order to control the width of
the repair area. • If you use a decal, ensure that the die-cut metering slot
is the same width as the grid line. • Thoroughly stir the grid line repair material until a uniform
color appears. • Ensure that there are no air bubbles in the grid line repair material
in the area being repaired.
Notice: The grid line repair material must be cured with heat. To avoid heat damage to the interior trim, protect the trim near the repair area where heat is to be applied.
Important:
• In order to completely cure the repair materials, heat at least
24 hours at an ambient temperature of 21-32°C (70-90°F) • Do NOT disturb the repair area until after the repair materials
are fully cured. • The grid line operates immediately after the repair.