Removal Procedure
Tools Required
J 38864 Counterbalance
Spring Removal and Installation Tool
- Remove the front door trim panel. Refer to
Door Trim Panel Replacement
.
- Remove the front door water deflector. Refer to
Front Side Door Water Deflector Replacement
.
- Apply the cloth backed body tape from the window over the top
of the door to the other side of the window in order to hold the window in
position when the removing the regulator.
- Remove the wiring harness from the regulator motor.
Important: Draw a line across the spring through the center with a marker or grease
pencil in order to aid in the re-installation and orientation of the counterbalance
spring.
- Use J 38864
to
walk down the spring tension.
- Unsnap the power window
motor in order to remove the power window motor from the lock module.
Installation Procedure
Tools Required
J 38864 Counterbalance
Spring Removal and Installation Tool
- Lubricate the motor drive gear and the regulator sector teeth.
- Snap the power window
motor to the lock module in order to install the power window motor.
Important: Ensure the marker or grease pencil line from the removal procedure is
lined up. Lining up the mark will set the correct pre-tension of the counterbalance
spring.
- Use the J 38864
to install the counterbalance spring.
- Install the wiring harness to the regulator motor.
- Install the front door water deflector. Refer to
Front Side Door Water Deflector Replacement
.
- Install the front door trim panel. Refer to
Door Trim Panel Replacement
.