Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is ON while the HVAC control is in the OFF position. | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 |
Is the blower motor OFF? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Does the scan tool indicate that the Desired Blower Mtr Speed parameter is near the specified value? | 0 counts | Go to Step 4 | Go to Step 7 |
4 | Disconnect the HVAC control module. Does the blower motor continue to operate? | -- | Go to Step 5 | Go to Step 7 |
5 | Inspect or test the blower motor housing and the blower motor speed control circuit in the blower motor harness for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 6 |
6 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 8 |
7 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 9 |
8 | Replace the blower motor control processor. Refer to Blower Motor Control Module Replacement . Did you complete the replacement? | -- | Go to Step 10 | -- |
9 | Replace the HVAC control module. Refer to HVAC Control Module Replacement for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |